Hot-water baseboard is a loop of pipe and fins along the wall. A boiler heats the water, a circulator moves it, and a zone valve or the pump starts when the thermostat calls for heat. The thermostat for that job is a low-voltage hydronic control. It is not the line-voltage dial screwed into an electric baseboard heater.
Using the electric version on a hot-water system is the wrong part. Those thermostats switch 120 or 240 volts for a heater element. A hydronic thermostat switches a valve or a relay. The current listing that says hydronic is this Honeywell TL8100.

What to look for
Hydronic, not electric
If the baseboard has a pipe and gets hot from water, you need a hydronic thermostat. If the heater is an electric element, you need a line-voltage thermostat instead.
What it switches
Most hot-water zones use a valve or a circulator relay. The new thermostat has to match that control, not just the shape of the old plate.
A schedule
Baseboard is slow. Set the temperature back only a few degrees, or the room will still be cold an hour after the boiler starts.
No Wi-Fi on this model
The TL8100 is a programmable wall control. You set the schedule on the thermostat. There is no phone app.
Top pick
A programmable Honeywell made for hydronic heat. It is not a Wi-Fi thermostat and it is not a line-voltage electric-baseboard control.
Check price on AmazonInstall the TL8100 on a hot-water zone when you want different temperatures for wake, day, evening, and sleep, and you do not need an app. Because baseboard heats slowly, program the morning temperature to start before you get up. A deep setback overnight often feels like the heat is broken at breakfast. Keep doors open in the zone so the thermostat, which only senses the room it is in, is not heating a closed-off hallway while the bedrooms stay cold. Compare the wiring diagram with the old thermostat. Zone valves and pump relays do not always use the same terminals.
Electric Heaters Are a Different Thermostat
If the baseboard has no water pipe and the old control is a high-voltage dial in the heater or on a 240-volt circuit, use a line-voltage thermostat for that heater. Screen size is a separate choice, covered on thermostats with an extra-large display, and battery models are on thermostats that run on a battery.
After It Is on the Wall
Program wake, day, evening, and sleep with only a few degrees between them, and start the morning setting early enough for the boiler to heat the water. The fins warm the room slowly. If one room in the zone stays cold, look for a closed door, furniture pushed against the fins, or air in that loop. The thermostat can only satisfy the room where it hangs.
Hot Water and Electric Baseboard Are Different Heat
Hot-water baseboard is a pipe and a row of fins. A boiler heats the water, a pump moves it, and a zone valve or relay opens when the thermostat calls. The thermostat is a low-voltage switch. Electric baseboard is a heating element on a 120- or 240-volt circuit, and its thermostat switches that voltage. The two parts do not substitute for each other.
If you can see a copper pipe entering the end of the heater, you are on the hydronic side. If the old control is a high-voltage dial in the heater itself, you are on the electric side. Guessing wrong means buying a control that cannot connect to the system you have.
Why the Schedule Should Stay Shallow
Baseboard heats slowly. The boiler, the water, and then the fins all have to warm up before the room does. A deep overnight setback leaves the kitchen cold at breakfast even though the thermostat clicked on an hour earlier. A few degrees between wake, day, evening, and sleep, with the morning period starting early, matches the way the heat actually arrives.
The Thermostat Only Knows One Room
It satisfies the air around it. A closed bedroom on the same zone will lag behind a hallway thermostat. Keep doors open, keep furniture off the fins so air can rise through them, and bleed a loop that gurgles and stays cold at the far end. The schedule cannot fix a blocked fin or air trapped in the pipe.